COVNA HK60-Q-3PS Series Electric Ball Valve

COVNA HK60Q-3PS electric ball valve, standard on/off control, 4-20mA or 0-10VDC modulating control is available, stainless steel body construction, optional WCB, 220VAC standard voltage, minimum 1/4 inch female thread connection, default PTFE seat, resistant to almost all fluids. Suitable for higher operating pressures and temperatures. Size range available in 1/2 inch, 3/4 inch, 1 inch, 1 1/4 inch, 1 1/2 inch, 2 inch, 2.5 inch, 3 inch and 4 inch. Voltage optional: 12V, 24V DC; 24V, 110V, 220V, 380V AC.
Welcome to contact us to get the most competitive electric ball valve price!

  Model   HK60-Q-3PS
  Torque Range   50Nm to 4000Nm
  Size Range   1/4in to 4in (1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″, 2″, 2-1/2″, 3″, 4″)
  Pressure   10bar, 16bar, 25bar, 40bar, 64bar
  Temperature Range   -10℃ to 180℃ (14℉ to 356℉)
  Voltage Options   DC-12V, 24V

  AC-24V, 110V, 220V, 380V

  Medium   Water, Wastewater, Seawater, Air, and another medium
COVNA Electric 3Pieces Stainless Steel Ball Valve
● Features: Compact Design, Eco-friendly, Easy Installation, etc
● Torque: 50N.m or 4000N.m
● Rotation: Quarter-turn
● Actuator Type: ON OFF Type, Regulating Type and Intelligent Type
● Material: Stainless Steel
● Connection: 3PC Thread, Tri Clamp, Flange and Welding
● Suitable for water, oil, air, etc. Widely used in HVAC, irrigation, water treatment, etc.



Technical Parameter of Valve Body:
Body Material Stainless Steel 304/316/316L Working Pressure 10 / 16 / 20 / 64 bar
Temperature Of Media -30~180℃ (-22℉~356℉) Suitable Media Water, Air, Oil, Gas, etc
Structure Straight Through Flow Path Voltage DC-12V, 24V; AC-24V, 110V, 220V, 380V 
Port size range DN08-DN100 Voltage Tolerance ±10%
Actuator Type ON OFF Type, Modulating Type, Intelligent Type, Explosion-proof Type and Multi-turn Type Port Thread Threaded/Flanged/Welding/Tri-clamp
 


Dimension of 3-Piece Electric Ball Valve:


 


Technical Parameter of Valve Body: 

  Nominal Size   DN15-DN200   Body Material   PVC, UPV, CPVC, PVDF and PPH
  End Connection   True Union, Double Union Thread   Structure   T Port / L Port
  Operating Pressure   1.0 / 1.6 MPa (10 / 16 bar)   Voltage Tolerance   ±10%
  Suitable Media   Corrosive media, Water, Air, etc   Temperature Of Media   -5~80℃ (23℉~176℉)
  Design standard   ISO, DIN, IDF, SMS, 3A   Orifice(mm)  15, 20, 25, 32, 40, 50, 65, 80, 100



Package & Shipping:
As a professional electric ball valve manufacturer, COVNA aims to provide our customers the best quality products with the most competitive pricing, on-time delivery and full warranty service with omprehensive service from start to finish, encompassing consultation through to after sales service, full support in every respect and ensure that you are accompanied at each stage of your project.


Company Profile:



Factory Profile:


Company Certificates:


Purchase Guide:

● Confirm the valve size you need. We offer this electric actuated ball valve in 1/2in to 8in.

● Confirm the valve body material you need. We offer this electric 3ps actuated ball valve in CF8 and CF8M materials

● Confirm the connection standard. We offer this electric actuated ball valve in ANSI, JIS, DIN, and UK standard.

● Confirm the pressure and working temperature. Pressure and temperature are the important points and those may affect the cost.

● Confirm the voltage you need. The right voltage could help your valve operate better.

● Tell us your medium. Different medium has different features and we will help you to select the valve basic on the medium requirements

● Confirm the actuator type you need. We have on/off type, modulating type, intelligent type, explosion-proof type, IP68 type and auto return type electric valve actuator for your project.

Any requirements please tell us like core material, sealing material, or connection standard. We could help you to custom the valve you need.

More infomation, please send message to us. Quote will be provided within 2 hours! [email protected]

Technical Parameter of Actuators: 
  Model   5   10   16   30   60   125   250   400
  Torque Output   50Nm   100Nm   160Nm   300Nm   600Nm   1250Nm   2500Nm   4000Nm
  90°Cycle Time   20s/60s   15s/30s/60s   15s/30s   15s/30s   30s/60s   100s   100s   100s
  Angle of Rotation   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°
  Working Current   0.25A   0.48A   0.68A   0.8A   1.2A   2A   2A   2.7A
  Starting Current   0.25A    0.48A   0.72A   0.86A   1.38A   2.3A   2.3A   3A
  Drive Motor   10W/F   25W/F   30W/F   40W/F   90W/F   100W/F   120W/F   140W/F
  Product Weight   3kg   5kg   5.5kg   8kg   8.5kg   15kg   15.5kg   16kg
  Voltage Option   AC 110V, AC 220V, AC 380V, DC 12V, DC 24V
  Insulation Resistance   DC24V:100MΩ/250V; AC110/220V/380V: 100MΩ/500V
  Withstand Voltage   DC24V:500V; AC110/220V:1500V; AC380V:1800V 1Minute
  Protection Class   IP65
  Installation Angle   Any
  Electrical Connection   G1/2 Water-proof Gable Connectors, Electric Power Wire, Signal Wire
  Ambient Temp.   -30℃to 60℃
  Control Circuit
  A: ON/OFF type with light indicator signal feedback
  B: ON/OFF type with passive contact signal feedback
  C: ON/OFF type with resistance potentiometer signal feedback
  D: ON/OFF type with resistance potentiometer and neutral position signal feedback
  E: Regulation type with servo control module
  F: DC24V/DC12V dirct ON/OFF type
  G: AC380V three-phase power supply with passive signal feedback
  H: AC380V three-phase power supply with resistance potentiometer signal feedback
Optional Function   Over Torque protectors, dehumidify heater, stainless steel coupling & yoke


3D Display of Electric Valve:

Installation Precautions:
● Before installing the valve, clean the line of dirt, scale, welding chips, and other foreign material Clean gasket surfaces thoroughly to insure leak-proof joints.
● Verify that the valve breakaway torque is less than the rated output torque of the actuator.
● Any mechanical stops that would interfere with the operation of the actuator must be removed before installation of the actuator, i.e. lever, travel stops, etc.
● The actuator output coupling must be centered with the valve stem to prevent side loading, which causes premature stem packing wear.
● To use the manual override feature (identified on cover label), the override shaft must be pressed down firmly at least 1/4" in order to disengage the motor from the gears. The manual override is not designed to overcome torque in excess of the rated torque of the actuator. Serious damage to the gear system may result from excessive turning force on the manual override.
● This Series actuator may be mounted in any position, i.e. horizontal, upside down. If the conduit entrance points upward, conduit piping must be oriented as to prevent condensation from enteringthe actuator from the conduit pipe.

Installation environment:

● The product can be installed indoor and outdoor, The surrounding environment temperature should be in -30°C~+60°C
● Product is non-explosion-proof production, and the installation must be avoided being in flammable or explosive environment etc.
● The actuator should be in protection box in the environment of long-term with the splash of rain, material and direct sunlight.
● Please reserve space for controller, manual operation.
★ The surrounding environment temperature should be in -30°C~+60°C.

Installed on the valve body:
● Manually operate the actuator to drive the valve, confirm it does not have abnormal situation. Turn the valve in full closed position.
● Assemble the bracket to the valve body.
● Set one end of couplings on valve spindle.
● Turn the electric actuator to full closing position, and insert output-input shaft into the square holes of couplings.
● Set the screw between the electric actuator and bracket.
● Turn actuator by hand shank, confirm that it moves translation, no eccentric, no skew and no overrun.


Cable installation:
● Install wire tubes, The outside diameter of wire tubes should be $9-411. Take measures to proof water. To prevent actuator from flowing into wire tubes water, the actuation position should higher than wire tubes position.
● When installing wire, the outside diameter of wire should be $9-φ11. in case the water flow into actuator interior from line locking, all wire that are not allowed to be used.
● The signal wire should be shielded wire in principle, don't parallel it to power wire.

Special tips:
● Caution: can't connect one actuator parallel with one another, in other words, can't use the same controller contact point to control more than one actuator, otherwise it will cause out of control, motor overheating, product damage, shorter service life.
If the actuator is installed outdoor, we suggest equipping other protective cover to proof water, stabilize mechanical property, make a longer service life.
 

Let’s Help

FAQ’s
Free Consultation